Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Alert: Due to routine maintenance on the OSHA website, some pages may be temporarily unavailable.
To report an emergency, file a complaint with OSHA or ask a safety and health question, call 1-800-321-6742 (OSHA).

Accident Report Detail

Accident: 87046.015 - Employee Is Electrocuted By Contact With Transformer And Is

Accident: 87046.015 -- Report ID: 0626600 -- Event Date: 07/24/2016
InspectionOpen DateSICEstablishment Name
1164201.01507/24/2016Centerpoint Energy Houston Electric, Llc
At 9:30 p.m. on July 24, 2016, an employee was preparing to connect a residentia l drop cable to a transformer. At some point, the employee made contact with the secondary bushings resulting in an electric shock. A journeyman located in an adjacent yard observed the employee slumped over the transformer and went over t he fence to remove the employee from the 240 volt transformer. The employee was transported to the hospital where he later died.
Keywords: electrical, electrocuted, transformer vault
Employee # Inspection Age Sex Degree Nature Occupation
1 1164201.015 32 M Fatality Electricians' apprentices

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close