Accident Report Detail
Accident: 869206 - Employee Pinned By Falling Steel And Is Killed
Accident: 869206 -- Report ID: 0522000 -- Event Date: 11/13/1989 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
101238525 | 11/13/1989 | 3443 | Riwco Corp. | ||||
Employee # 2 was operating a twenty ton overhead crane and was lifting a large draft tube assembly measuring 191 inches long by 132 inches high made of ten large steel plates of 0.75-in.-thick steel with individual dimensions of approximately 5ft by 10.5ft. The assembly was attached with a two leg sling and fastened to a lifting lug approximately at the center to balance the load. The weld on the lug broke and the assembly dropped. It fell on Employee #1, pinned him against a steel parts bin and killed him. | |||||||
Keywords:
crane hook, struck against, suspended load, overhead crane, struck by, sling, crane operator, crane
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 101238525 | Fatality | Other | Welders and cutters |