Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 86050.015 - Employee Sustains Puncture Wound To Abdomen And Is Killed Wh

Accident: 86050.015 -- Report ID: 0317900 -- Event Date: 06/16/2016
InspectionOpen DateSICEstablishment Name
1155295.01506/16/2016Allentown Steel Fabricating Co., Inc.
At approximately 8:00 a.m. on June 16, 2016, an employee was straightening 0.75- inch steel plates approximately 27.875-in. long by 9.8125-in. wide, on a 1000-To n Cincinnati Hydraulic Press Brake. The employee had placed a 1.75-in, steel blo ck (3-in. by 1.5-in.) on top of the steel plate and a shim (piece of steel bandi ng material approximately 0.032-in. thick) believed to be approximately 3 inches in length on top of the steel block. When the press was actuated, it appears th at the shim broke apart, propelling pieces out the front and rear of the press b ed. The employee standing in front of the press was apparently struck in the ab domen by one or more pieces of the metal. The employee sustained puncture wounds to the abdomen and was killed.
Keywords: abdomen, flying object, hydraulic press, press brake, puncture, struck by
Employee # Inspection Age Sex Degree Nature Occupation
1 1155295.015 53 M Fatality Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close