Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 827063 - Employee Crushed And Killed By Transfer Arm Of Punch Press

Accident: 827063 -- Report ID: 0751910 -- Event Date: 07/29/1988
InspectionOpen DateSICEstablishment Name
10421412707/29/19883633W C I Laundry Division
Employee #1 was trying to locate a problem with a lift table for a punch press. He was crushed and killed between the material transfer arm (bar) and the frame of the turnover unit. Employee #1 had always worked in the unit with the power on. The employer has a lockout procedure, it had not been enforced.
Keywords: maintenance, work rules, lockout, caught between, crushed, punch press
Employee # Inspection Age Sex Degree Nature Occupation
1 104214127 Fatality Other Industrial machinery repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.