Accident: 822239 - Employee'S Face Fractured When Struck By Exploding Tire Rim

Accident: 822239 -- Report ID: 0352440 -- Event Date: 01/05/1989
InspectionOpen DateSICEstablishment Name
10840979801/05/19895531Performance Discount Tire Co Inc
At approximately 12:10 p.m. on January 5, 1989, Employee #1, a tire mechanic, was in the service area of a shop using a Coats 40-40 SA tire changer to mount a new Dunlap radial all- purpose tire and single piece rim wheel. The tire, size 232/85R16 (16 in. bead diameter with a 16 1/2 in. head diameter), did not look right to the employee while he was inflating it, so he leaned over it to check the bead. As he did, the tire exploded. The tire and rim struck him in the face and he was hospitalized for treatment of facial fractures. Employee #1 had not checked the sizes of the tire and the rim before mounting the tire. To set the bead, he used an air hose with 115 psi without a clip-on chuck. The hose was not approved for use with the tire changer. Employee #1 also did not check the air pressure with a gauge. To complete the inflating process, he attached the air hose, which was part of the tire changer and had a clip on the chuck. Employee #1 had removed the hold-down cone (restraining device) before the tire was firm. Charts and the manufacturer's critical safety warning and operation instructions for the tire changer were not available. The employer did not have a safety program to instruct employees on how to service single piece rim wheels.
Keywords: fracture, single piece rim, work rules, mechanic, explosion, restraining device, inflating, struck by, face, tire
Employee # Inspection Age Sex Degree Nature Occupation
1 108409798 Hospitalized injury Fracture Garage and service station related occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close