Accident: 818369 - Employee Killed In Fall To Concrete Slab

Accident: 818369 -- Report ID: 0418800 -- Event Date: 06/19/1989
InspectionOpen DateSICEstablishment Name
1839463506/21/19891751Gamez Services Inc.
Employee #1 working on a curved concrete boom lost his balance and fell 20 ft to the concrete slab and was killed, when the rachet handle extension broke or disengaged. The worksite was without fall protection or guardrails.
Keywords: concrete slab, guardrail, boom, fall, fall protection, concrete
Employee # Inspection Age Sex Degree Nature Occupation
1 18394635 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.