Accident: 793638 - Employee Killed When Struck By Unidentified Flying Object

Accident: 793638 -- Report ID: 1054118 -- Event Date: 04/07/1992
InspectionOpen DateSICEstablishment Name
11569623904/07/19922421Rsg Forest Products Inc
On or about April 6, 1992, Employee #1, a log buyer for RSG Forest Products, Inc., dba Estacada Lumber Co., was on a routine check of a contract logger at Estacada. Employee #1 and the owner of the logging company were walking to their pickups, when the TMY 70 yarder had an apparent guyline failure while yarding either the second or third turn in after lunch. The guyline failure, in turn, caused the next line to fail and shot the rigging of the two guylines through the landing area. Employee #1 was struck in the back of the head by an as yet undetermined object. He suffered a severe head injury and was transported by Life Flight to OHSU, where he later died of his injuries.
Keywords: head, yarding, equipment failure, guy, struck by, flying object
Employee # Inspection Age Sex Degree Nature Occupation
1 115696239 Fatality Other Forestry workers, except logging

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close