Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 767442 - Electric Shock - Contact With Overhead Line Thru Boom

Accident: 767442 -- Report ID: 0626300 -- Event Date: 01/20/1992
InspectionOpen DateSICEstablishment Name
10754853901/22/19921611Traylor Bros., Inc.
AN EMPLOYEE WAS GUIDING A LOAD ATTACHED TO A TRUCK CRANE. THE BOOM OF THE CRANE CONTACTED A 13-KILOVOLT OVERHEAD POWER LINE, AND THE EMPLOYEE WAS ELECTROCUTED.
Keywords: overhead power line, electrical, boom, crane boom, electrocuted, e gi ia, crane
Employee # Inspection Age Sex Degree Nature Occupation
1 107548539 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close