Accident Report Detail
Accident: 756445 - Employee Killed When Caught Between Two Manhole Pipes
Accident: 756445 -- Report ID: 0855610 -- Event Date: 10/25/1993 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
114619398 | 10/26/1993 | 9199 | City Of Cody | ||||
Inspection | Open Date | SIC | Establishment Name | ||||
114619406 | 10/26/1993 | 1623 | Hays Brothers Welding Inc | ||||
Employee #1 was building a manhole consisting of stacked concrete pipes reaching a height of approximately 20 ft. He was inside the manhole guiding one pipe on top of another, using a backhoe crane, chains, and abar for hoisting. The lowered pipe was not lined up. Employee #1 motioned the crane operator to try again, not realizing that the chain had slipped off the bars. When the operator tried to lift the pipe it tilted, pinning Employee #1 between two concrete manhole pipes. He was killed. | |||||||
Keywords:
slip, pipe, manhole, inattention, chain, pinned, construction, caught between
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 114619398 | Occupation Not Listed | |||||
2 | 114619406 | Fatality | Bruise/Contus/Abras | Supervisors, material moving equipment operators |