Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 739342 - Employee Struck And Killed By Falling Concrete Slab

Accident: 739342 -- Report ID: 0452110 -- Event Date: 12/10/1992
InspectionOpen DateSICEstablishment Name
12381397412/10/19928211Wayland Alexander Elementary School
Employee #1 was bending over at the east side of a basement area. A trackhoe operator did not have Employee #1 in view and let go of the controls, causing the trackhoe to move and hit a wall. The wall broke and a slab of concrete landed on Employee #1, killing her instantly.
Keywords: concrete slab, wall, obstructed view, struck by, falling object
Employee # Inspection Age Sex Degree Nature Occupation
1 123813974 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close