Accident Report Detail
Accident: 736827 - Employee Struck In Head By Descending Power Press Die
Accident: 736827 -- Report ID: 0452110 -- Event Date: 03/14/1986 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
102015872 | 04/08/1986 | 3469 | Porcelain Metal Corporation | ||||
EMPLOYEE #1 WAS REMOVING PARTS AND SCRAP METAL FROM THE DIES ON A MECHANICAL POWER PRESS. THE PRESS WAS SOMEHOW TRIPPED, CAUSING THE UPPER DIE TO DESCEND AND STRIKE THE EMPLOYEE IN THE HEAD. HE WAS HOSPITALIZED. | |||||||
Keywords:
die, head, power press, work rules, cleaning, lockout, struck by
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 102015872 | Hospitalized injury | Fracture | Punching and stamping press machine operators |