Accident Report Detail
Accident: 735456 - Employee Killed When Caught In Chain And Sprocket Drive
Accident: 735456 -- Report ID: 0454510 -- Event Date: 02/09/1987 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
105445308 | 02/11/1987 | 2421 | Georgia-Pacific Corporation | ||||
Employee #1 and a coworker were under an Ad Cowest edger (Serial No. 10727) placing a chain back on the sprocket for the transfer table drive, which was the only equipment involved. While Employee #1 was installing the chain, the drive started back up and his jacket was caught in the drive, pulling him into the sprocket. Employee #1 sustained head trauma and was killed. The machine had not been locked out before the employees started working on it. | |||||||
Keywords:
chain, clothing, head, repair, work rules, caught by, lockout, sprocket
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 105445308 | Fatality | Other | Supervisors, mechanics and repairers |