Accident: 731877 - Employee'S Fingers Amputated In Power Press
Accident: 731877 -- Report ID: 0551800 -- Event Date: 04/02/1985 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
2757086 | 04/15/1985 | 3465 | Lobdell Emery Mfg Co | ||||
At approximately 5:45 a.m. on April 2, 1985, Employee #1 was placing and moving metal parts on a Vurson 250 ton part revolution mechanical power press, model #SS2-250-144-48T. The press was forming and stamping parts. The employee was standing beside the press, using his hand to place the parts on the side. The blade and latch control developed a broken brake ring. The wheel pinned the piston that engaged the latch, allowing the press to run continuously while putting pressure on the housing wheel's brake. Employee #1 had his right hand in the point of operation when the press started. Four of his fingers were amputated and he was hospitalized. | |||||||
Keywords:
amputated, die cutting press, power press, finger, work rules, equipment failure, lockout, press operator
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 2757086 | Hospitalized injury | Amputation | Punching and stamping press machine operators |