Accident: 69606.015 - Employee Is Crushed By Lift Bucket And Is Killed
Accident: 69606.015 -- Report ID: 0419700 -- Event Date: 12/17/2014 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1014989.015 | 12/18/2014 | Waste Pro Of Florida, Inc. | |||||
At 11:40 p.m. on December 17, 2014, Employee #1 was working under the raised met al bucket of a recycling truck body to change an air shifter solenoid valve on t he truck body's hydraulic system. The hydraulic oil started to bleed out when th e employee removed the solenoid valve. As a result of the loss of hydraulic pres sure, the metal bucket fell down on top of Employee #1, crushing and killing him . | |||||||
Keywords:
crushed, falling object, garbage truck, hydraulic fluid, lockout/tagout, pressure release, struck by, valve
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 1014989.015 | 25 | M | Fatality | Technicians, n.e.c. |