Accident Report Detail

Accident: 688895 - Employee Hospitalized After Exposure To Carbon Monoxide

Accident: 688895 -- Report ID: 0522300 -- Event Date: 11/02/1995
InspectionOpen DateSICEstablishment Name
12193445911/07/19953669Genie Co.
After work on November 1, 1995, Employee #1 sought medical attention. Although he is a non-smoker, his carboxyhemoglobin level was 11 percent. He informed the employer the next day. Several other employees then went to various hospital emergency rooms. Employees #1 through #12 were admitted and treated overnight. Some of the employees were given hypobaric treatment. Their carboxyhemoglobin levels were 10 percent to 16.7 percent. The employer did carbon monoxide monitoring and found levels to be 85 to 132 ppm in and around the production area. Heaters were inspected and two were taken out of service until repaired. Lift truck tailpipes were tested and adjusted. Four propane lift trucks were replaced with electric trucks. Fresh air is provided through overhead doors and pedestal. Eight hour TWA carbon monoxide levels were measured at 1 to 10 ppm. There is now a related 11(c) case for an employee terminated for excessive absenteeism due to another incident of high carboxyhemoglobin levels in December.
Keywords: air contamination, carboxyhemoglobin, overexposure, carbon monoxide
Employee # Inspection Age Sex Degree Nature Occupation
1 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
2 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
3 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
4 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
5 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
6 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
7 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
8 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
9 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
10 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
11 121934459 Hospitalized injury Poisoning(Systemic) Assemblers
12 121934459 Hospitalized injury Poisoning(Systemic) Assemblers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.