Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 672063 - Employee'S Fingers Amputated By Press Brake

Accident: 672063 -- Report ID: 0551800 -- Event Date: 08/17/1987
InspectionOpen DateSICEstablishment Name
10405271708/19/19873993H-N Advertising & Display Co Inc
At 8:30 a.m. on August 17, 1987, Employee #1 was placing and removing metal parts on a Niagara mechanical press brake, serial #46950. The brake was tripped by a foot pedal and equipped with light curtains. Employee #1 was taking a sheet metal part out of the die when the brake double-tripped and amputated three fingers on her right hand. Employee #1 was hospitalized.
Keywords: die, amputated, brake, press brake, finger, mech malfunction
Employee # Inspection Age Sex Degree Nature Occupation
1 104052717 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close