Accident: 671438 - Employee'S Hand Crushed In Power Press

Accident: 671438 -- Report ID: 0551800 -- Event Date: 08/19/1986
InspectionOpen DateSICEstablishment Name
10199327708/21/19863354Hoosier Trim Products
AT APPROXIMATELY 11:30 PM ON AUGUST 19, 1986, EMPLOYEE #1 WAS REMOVING A PART FROM THE DIE OF A BLISS, 93 TON MECHANICAL POWER PRESS. THE PRESS ALLEGEDLY DOUBLE TRIPPED, CATCHING HER HAND BETWEEN THE OUTER FLANGES OF THE DIE. HER RIGHT HAND WAS CRUSHED, BUT NO BONES BROKEN. THE ACCIDENT COULD HAVE BEEN PREVENTED THROUGH THE INSTALLATION OF A POINT OF OPERATION GUARD.
Keywords: die, power press, crushed, point of operation, hand, press, unguarded
Employee # Inspection Age Sex Degree Nature Occupation
1 101993277 Hospitalized injury Bruise/Contus/Abras Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.