Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 648543 - Employee Killed In Fall From Viaduct

Accident: 648543 -- Report ID: 0215000 -- Event Date: 06/18/1993
InspectionOpen DateSICEstablishment Name
10693363306/21/19931791Gem Erectors Co., Inc.
Employee #1, an iron worker on a highway viaduct rehabilitation project, was replacing rivets in a roadway support beam when the beam broke loose from its connection. Employee #1 and the work platform planks fell 55 feet to the ground. He was killed. Employee #1 had failed to replace the rivets he had removed and to connect the safety belt he was wearing to a safety lifeline cable.
Keywords: beam, unsecured, iron worker, work rules, construction, fall, fall protection, tie-off
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Highway, road, street Alteration or rehabilitation $20,000,000 and over 55 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 106933633 Fatality Other Occupation not reported FallDist:
FallHt:55
Cause: Erecting structural steel
FatCause: Fall from/with platform catwalk (attached to struc

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.