Accident: 640805 - Employee'S Thumb And Index Finger Amputated In Power Press

Accident: 640805 -- Report ID: 0213900 -- Event Date: 10/01/1992
InspectionOpen DateSICEstablishment Name
10735609910/01/19922542International Rollform Inc.
Employee #1, of International Rollform, Inc., Deptford, NJ, was operating a 60-ton Bliss 6-60W air clutch/brake mechanical power press. He was performing a secondary operation on preworked stock, bending the rim of a can-shaped aluminum part being produced for use as a recessed lighting fixture. Employee #1 was attempting to retrieve the part from the machine's point of operation when his right thumb and index finger were partially amputated. Some of the accident's causal factors are the lack of control system reliability, brake system monitoring, and a dual solenoid valve to prevent significant increase in the normal stopping time due to failure of the operating valve mechanism.
Keywords: amputated, brake, power press, finger, work rules, caught by, thumb, equipment failure, point of operation
Employee # Inspection Age Sex Degree Nature Occupation
1 107356099 Hospitalized injury Amputation Machinist apprentices

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close