Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 63829.015 - Two Employees Suffer Asphyxiation During Rail Tank Car Inspe

Accident: 63829.015 -- Report ID: 0524500 -- Event Date: 06/24/2014
InspectionOpen DateSICEstablishment Name
982626.01506/24/2014Agridyne, L.L.C.
At 12:30 p.m. on June 24, 2014, Employee #1 was performing internal non-destructive thickness measurements inside of the rail tank cars after cleaning. Employee #1 entered the third rail tank car by climbing down a ladder. When reaching the bottom, Employee #1 realized that something was wrong and tried climbing back up the ladder. Employee #1 reached the top of the car and reached out to a coworker for assistance who was unable to get a firm grip on the employee. Employee #1 fell from the ladder back into the tank car and became unresponsive. Employee #2 entered the car to rescue Employee #1 and was also overcome due to the hazardous atmospheric conditions inside the tank car. The fire department retrieved both employees and transported Employee #1 to the hospital where he was pronounced dead approximately 1 hour later. Employee #2 was pronounced dead at the scene.
Keywords: toxic atmosphere, asphyxiated, fall, ladder, confined space, railroad tank car
Employee # Inspection Age Sex Degree Nature Occupation
1 982626.015 29 M Fatality Asphyxia Inspectors, testers and graders
2 982626.015 37 M Fatality Asphyxia Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close