979641.01506/05/2014Worldwide Construction & Restoration, Inc
At 5:00 a.m. on June 7, 2017, two employees were working from the basket of an a eral lift on the west side of an existing building applying a self adhesive plas tic film to the outside of windows and frames to protect them when the building was painted once prepared. The highest elevation that the employees needed to ac cess was approximatly 21 feet (roof edge) above a lower level. There were overhe ad power and communication lines running parallel to the building where the thre e lowest wires near the work area were Telephone at 19 feet, Cable TV at 19 feet 10 1/2 inches, and a Neutral (ground) wire at 23 feet 7 3/4 inches above the gr ound and all three were approximately 5 feet 6 inches away from the building. Th e two highest wires were high voltage (7,620 volts) which were approximately 36 feet 2 inches above ground level and not accessible when working between the com muinication wires and building while under the building soffit which overhung th e work area. At some point the employees lowered the lift enough to go under the communication wires, moved away from the building, then elevated the lift baske t and themselves to the height of the powerlines where one empoloyee made contac t with what seems to be the side of his head causing the basket and lift to also become energized shocking and injuriing the second employee occupying the baske t. The employees were both transported to and admitted into a local hospital. On 06/07/2014 one of the employees passed away at the hospital due to his injuries . The other employee sustained shock and burns to the head and hands.
Keywords: aerial lift, power lines
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Multi-family dwelling Alteration or rehabilitation Under $50,000 2 21 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 979641.015 25 M Fatality Construction trades, n.e.c. FallDist:
FallHt:
Cause: Exterior painting
FatCause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.