Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 607911 - 1 Employee Killed, 1 Injured From Carbon Dioxide Exposure

Accident: 607911 -- Report ID: 0418100 -- Event Date: 12/05/1987
InspectionOpen DateSICEstablishment Name
10127611102/02/19882813Liquid Carbonic
InspectionOpen DateSICEstablishment Name
217345812/08/19877349Defender Industries, Inc.
InspectionOpen DateSICEstablishment Name
10127607912/08/19872011Eaves Packing Company
SOMETIME BETWEEN 12:30 AND 1 AM ON DECEMBER 5, 1987 A PRESSURIZED LIQUID CARBON DIOXIDE LINE RUPTURED AT THE EAVES PACKING COMPANY. THE LINE RUNS FROM AN OUTSIDE STORAGE TANK TO A MEAT BLENDER INSIDE THE BUILDING. EMPLOYEES #1 AND #2 WERE PART OF A CONTRACT CLEAN-UP CREW THAT WAS CLEANING THE MEAT PROCESSING ROOM AND EQUIPMENT WITH PRESSURIZED WATER HOSES. THEY WERE LOCATED WITHIN 40 FEET OF THE AREA OF THE RUPTURE JUST BEFORE THE CARBON DIOXIDE BEGAN LEAKING. ACCORDING TO A WITNESS, EMPLOYEE #1 MAY HAVE BEEN ON A LADDER DIRECTLY UNDER THE PIPE THAT RUPTURED. THE ROOM BECAME VERY FOGGY AND COLD IMMEDIATELY AFTER THE RUPTURE. VISIBILITY WAS NEAR ZERO. EMPLOYEE #1 WAS FOUND TANGLED UP IN A ROLLER CONVEYOR THAT HAD BEEN KNOCKED OVER, PROBABLY BY EMPLOYEE #1 JUMPING IT TO GET TO AN EXIT. EMPLOYEE #2 WAS FOUND COLLAPSED AGAINST A WALL NEAR THE FRONT ENTRANCE. EMPLOYEE #2 SUFFERED FROSTBITE ON HIS LEFT HAND AND WEEKS LATER LOST ALL HIS FINGERS ON THAT HAND. TWO OTHER EMPLOYEES IN THE ROOM AT THE TIME OF THE RUPTURE ESCAPED WITHOUT HARM.
Keywords: respiratory, pipe, inhalation, finger, rupture, pressure piping, carbon dioxide, frozen
Employee # Inspection Age Sex Degree Nature Occupation
1 101276111 Occupation Not Listed
2 2173458 Hospitalized injury Freezing/Frost Bite Occupation not reported
3 2173458 Fatality Asphyxia Occupation not reported
4 101276079 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close