Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 606202 - Employee Crushed Between Diverter Gate And Beam

Accident: 606202 -- Report ID: 0418100 -- Event Date: 09/27/1986
InspectionOpen DateSICEstablishment Name
10186368609/29/19862411Augusta Newsprint Company
EMPLOYEE #1 WAS IN THE CONTROL ROOM SORTING LOGS WHEN A LOG JAM OCCURRED AT THE DIVERTER GATE AREA, LOCATED ABOVE THE DEBARKING DRUM. EMPLOYEE #1 LEFT THE CONTROL ROOM TO INVESTIGATE THE JAM AT THE DIVERTER GATE. HE WAS INVESTIGATING THE LOG JAM WHEN THE HYDRAULIC PUMP OVERHEATED, MOVING THE DIVERTER GATE AGAINST A STEEL BEAM AND CRUSHING HIM AGAINST THE BEAM. THE DISTANCE BETWEEN THE DIVERTER GATE AND THE BEAM WAS 10 INCHES. LOCKOUT PROCEDURES WERE NOT USED AT THE TIME OF THE ACCIDENT.
Keywords: beam, log, jammed, lockout, crushed, sawmill, overheated, pump, hydraulic pump
Employee # Inspection Age Sex Degree Nature Occupation
1 101863686 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.