Accident: 57451.015 - Two Employees Are Killed In Communications Tower Collapse

Accident: 57451.015 -- Report ID: 0316400 -- Event Date: 02/01/2014
InspectionOpen DateSICEstablishment Name
957188.01502/01/2014S. & S. Communication Specialists, Inc.
At 11:37 a.m. on February 1, 2014, two employees were removing tubular diagonal bracing from a communications tower. As they were replacing the bracing with ? i nch angle iron at a 60-70 ft section, the communications tower collapsed. Suffer ing crushing and impalement from the structural metal, both employees were kille d due to multiple injuries to the head, torso and extremities.
Keywords: communication tower, crushing, head, impaled, struck by, structural collapse, torso
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Other building Alteration or rehabilitation $250,000 to $500,000 340 X
Employee # Inspection Age Sex Degree Nature Construction
1 957188.015 27 M Fatality FallDist:
FallHt:
Cause: Emplacing reinforcing steel
FatCause:
2 957188.015 32 M Fatality FallDist:
FallHt:
Cause: Emplacing reinforcing steel
FatCause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.