Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 571620 - Exposed To 1,1,1 Trichloroethane Vapor

Accident: 571620 -- Report ID: 0521400 -- Event Date: 12/23/1984
InspectionOpen DateSICEstablishment Name
235147612/26/19843661Westell Inc
InspectionOpen DateSICEstablishment Name
235275512/26/19843661Westell Inc
InspectionOpen DateSICEstablishment Name
235147612/26/19843661Westell Inc
ON DECEMBER 23, 1984, 11 EMPLOYEES OF AN ELECTRONIC CIRCUIT BOARD MANUFACTURING FIRM WERE TRANSPORATED TO A HOSPITAL, TREATED FOR EXPOSURE TO 1, 1, 1, TRICHLOROETHANE VAPOR, AND RELEASED. THE EXPOSURE RESULTED WHEN A PRINTED CIRCUIT BOARD EDGE PROTECTOR, MADE OF NEOPRENE, FELL THROUGH A HOLE IN AN EXPANED METAL BASKET USED FOR THE DEGREASING OF PARTS. THE EDGE PROTECTOR LANDED ON ONE OF THE HEATING COILS IN THE DEGREASER, CAUSING IT TO OVERHEAT AND BURN, PRODUCING A TOXIC CLOUD OF 1, 1, 1, TRICHLOROETHANE. THE TOXIC CLOUD DISSIPATED THROUGH THE PLANT WHEN THE COVER ON THE DEGREASER WAS OPENED TO INVESTIGATE WHY SMOKE WAS LEAKING OUT THROUGH ONE SIDE OF THE COVER.
Keywords: respiratory, trichloroethane, vapor, degreaser, toxic fumes
Employee # Inspection Age Sex Degree Nature Occupation
1 2351476 Hospitalized injury Poisoning(Systemic) Electronic repairers, communica. & indus. equip.
2 2351476 Hospitalized injury Poisoning(Systemic) Electronic repairers, communica. & indus. equip.
3 2351476 Hospitalized injury Poisoning(Systemic) Electronic repairers, communica. & indus. equip.
4 2351476 Hospitalized injury Poisoning(Systemic) Electronic repairers, communica. & indus. equip.
5 2352755 Occupation Not Listed
6 2351476 Hospitalized injury Poisoning(Systemic) Electronic repairers, communica. & indus. equip.
7 2351476 Hospitalized injury Poisoning(Systemic) Electronic repairers, communica. & indus. equip.
8 2351476 Hospitalized injury Poisoning(Systemic) Electronic repairers, communica. & indus. equip.
9 2351476 Hospitalized injury Poisoning(Systemic) Electronic repairers, communica. & indus. equip.
10 2351476 Hospitalized injury Poisoning(Systemic) Electronic repairers, communica. & indus. equip.
11 2351476 Hospitalized injury Poisoning(Systemic) Electronic repairers, communica. & indus. equip.
12 2351476 Hospitalized injury Poisoning(Systemic) Electronic repairers, communica. & indus. equip.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.