Accident: 55988.015 - Employee Is Killed When Struck By Falling Object

Accident: 55988.015 -- Report ID: 0625400 -- Event Date: 12/17/2013
InspectionOpen DateSICEstablishment Name
953296.01512/17/2013Tarco Of Texas, Inc.
InspectionOpen DateSICEstablishment Name
953291.01512/17/2013Jasdem, Inc.
At 11:00 a.m. on December 17, 2013, an employee was power washing the inside of a tank that contained hardened asphalt coating. During washing of the tank, a large piece of hardened asphalt fell and struck the employee's legs. The employee fell and struck his head. The employee was killed.
Keywords: caught in, asphalt, falling object, confined space, tank cleaning, struck by
Employee # Inspection Age Sex Degree Nature
1 953296.015 19 M Fatality Bruise/Contus/Abras
2 953291.015 19 M Fatality Bruise/Contus/Abras

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.