Accident: 508895 - Diver Drowns When Air Hose Is Severed

Accident: 508895 -- Report ID: 1032100 -- Event Date: 09/12/1997
InspectionOpen DateSICEstablishment Name
30149421709/19/19973731Magone Marine Service Inc
Employee #1, a scuba diver, was installing a shackle onto a fixed anchor line in approximately 120 ft of water when, for some reason his high pressure hose was severed in two and he drowned. Causal factors contributing to this accident: (1) both primary and alternate regulators were in need of repair; (2) there was no flotation equipment with an air source separate from the breathing air supply; and (3) there was no standby diver. In addition, Employee #1 was using borrowed equipment that was unfamiliar to him, he was not line-tended, and he was not carrying a reserve air supply.
Keywords: severed, inadequate maint, scuba, work rules, air hose, drown, air line, diver, water
Employee # Inspection Age Sex Degree Nature Occupation
1 301494217 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.