Accident Report Detail
Accident: 44004.015 - Employee Is Crushed By Fence And Is Killed
Accident: 44004.015 -- Report ID: 0729700 -- Event Date: 04/29/2013 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
903121.015 | 04/30/2013 | Brookover Feed Yards, Inc | |||||
At 8:15 a.m. on April 29, 2013, Employee #1, a maintenance worker, was engaged in cutting down a 30 foot long, 350 pound cattle pen fence. The cattle pen fence was welded steel, manufactured locally from oil and gas piping. Employee #1 was using an acetylene torch, cutting the final connected vertical support of the fence. The fence had previously been cut free from a section of fencing to the east and four vertical supports. During the cutting operation on the final post, the fence post broke free and fell on Employee #1, crushing him in the sitting position, fracturing his neck and killing him. | |||||||
Keywords:
pipe, neck, maintenance, fracture, fence, crushed, steel, acetylene torch, struck by
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 903121.015 | 29 | M | Fatality | Fracture | Welders and cutters |