Accident: 41140.015 - Employee Contacts Overhead Power Line, Falls From Ladder, An

Accident: 41140.015 -- Report ID: 0112300 -- Event Date: 09/19/2012
InspectionOpen DateSICEstablishment Name
654578.01509/19/2012Jb Construction
At approximately 2:00 p.m. on September 19, 2012, Employee #1 was climbing an ex tension ladder and guiding a 4 ft by 8 ft sheet of plywood . The plywood sheet w as hoisted to an open section of a second story roof by a section of rope. As Em ployee #1 climbed the ladder, he contacted an energized overhead power line tha t was running parallel to the south side of the house and was measured approxima tely 12 in. from the ladder. The line voltage was 7,200 volts. The power lines w ere not guarded or otherwise made safe. After contacting the power lines, Employ ee #1 fell approximately 22 ft to the sidewalk. He sustained internal bleeding f rom blunt trauma to the head and torso and an electrical burn on the right index finger and is killed.
Keywords: electrical, fall, ladder, power lines, residential construction
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Multi-family dwelling Maintenance or repair $50,000 to $250,000 2 24 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 654578.015 50 M Fatality Roofers FallDist: 22
FallHt:25
Cause: Roofing
FatCause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.