Accident: 4008.015 - Employee Is Killed When Caught In A Portable Wood Chipper
Accident: 4008.015 -- Report ID: 0524530 -- Event Date: 11/18/2011 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
109246.015 | 11/18/2011 | Andrew T Jacobs | |||||
At 10:15 on November 18, 2011, an employee was feeding small limbs into a wood chipper from an oak tree, which the company was trimming from a residential site. The employee was operating a Vermeer BC 1800 Auto Feed II Wood Chipper. While feeding a Y-shaped branch into the machine, a portion of clothing caught on to the branch. The employee was drawn into the machine and was amputated from head to chest. The machine lacked a bottom-feed stop bar. | |||||||
Keywords:
tree trimming, tree limb, chipper, amputation, caught in
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 109246.015 | 52 | M | Fatality | Amputation | Laborers, except construction |