Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 302314505 - Employee Died After A Fall Off A Ladder

Accident: 302314505 -- Report ID: 0830600 -- Event Date: 01/28/2000
InspectionOpen DateSICEstablishment Name
30231443001/31/20008733Burns & Roe Services Corp.
On January 15, 2000, Employee #1 collecting brine samples from a 9-ft-tall, 1200-gallon fiberglass tank, fell approximately 6 ft off the ladder he was standing on while collecting a brine sample. Employee #1 hit his head on a concrete floor when he fell. He was hospitalized after the accident and died on January 27, 2000, from the head injuries. Employee #1 was working with brine containing hydrogen sulfide gas (H2S). Concentrations of H2S were measured after the accident and were 1000 ppm.
Keywords: head, hydrogen sulfide, ladder, fall, concussion, concrete
Employee # Inspection Age Sex Degree Nature Occupation
1 302314430 Fatality Concussion Industrial engineering technicians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close