Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 29675.015 - Employee Falls Through Roof Deck Opening, Suffers Unspecifie

Accident: 29675.015 -- Report ID: 0418100 -- Event Date: 09/24/2012
InspectionOpen DateSICEstablishment Name
655098.01509/25/2012Kayco Erectors, Inc.
At approximately 3:45 p.m. on September 24, 2012, Employee #1 was installing met al roof decking, approximately 20 ft above the ground. The 3 ft wide by 20 ft lo ng metal decking became displaced and shifted to the side, and exposed an openin g. Additionally, the metal decking was not secured and/or welded down to the be am and/or joist. Employee #1 was wearing a body harness and lanyard but was not tied off. As he worked, he fell through the opening, suffering unspecified injur ies and was killed.
Keywords: fall, roof, roof decking, roof opening, steel erection
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Commercial building New project or new addition $1,000,000 to $5,000,000 1 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 655098.015 28 M Fatality Structural metal workers FallDist: 20
FallHt:20
Cause: Steel Erection Of Open Web Steel Joists-Welding/Bu
FatCause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.