Accident: 26435.015 - Employee Contacts Power Line And Sustains Electrical Burns A

Accident: 26435.015 -- Report ID: 0418800 -- Event Date: 08/26/2012
InspectionOpen DateSICEstablishment Name
588966.01508/22/2012All Florida Tree & Landscape, Inc.
At 4:45 p.m. on August 21, 2012, Employee #1 was in a tree and trimming the tree 's branches. He was strapped to one of the tree branches and using a crane to li ft and remove the tree branches from the tree. Employee #1 used a chainsaw to cu t one of the tree branches. As he was cutting the limb, he contacted a power lin e and sustained electrical burns to his chin, right hand and inner thighs. He la ter died at approximately 4:45 p.m. on August 26, 2012 from injuries sustained i n the electrocution.
Keywords: burn, electrical, electrocuted, power lines, struck against, tree trimming
Employee # Inspection Age Sex Degree Nature
1 588966.015 31 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.