Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 25975.015 - Employee Was Electrocuted When He Came In Contact With Overh

Accident: 25975.015 -- Report ID: 0111100 -- Event Date: 08/08/2012
InspectionOpen DateSICEstablishment Name
570360.01508/09/2012Atlantic Paving Inc.
On August 8, 2012, an employee was working for a paving firm. He was spreading asphalt that was being dumped from an asphalt truck. The raised body of the asphalt truck came into contact with overhead power lines and became energized. The employee touched the asphalt truck while it was energized. He was electrocuted. He was found on the ground.
Keywords: road paving, asphalt, e gi ia, electrocuted, overhead power line, electric shock, construction
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Other heavy construction Maintenance or repair Under $50,000 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 570360.015 42 M Fatality Electric Shock Paving, surfacing and tamping equipment operators FallDist:
FallHt:
Cause:
FatCause: Electrocution from equipment installation/tool use

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.