Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 20316.015 - Employee Is Killed When Struck By Lid From Exploding Drum

Accident: 20316.015 -- Report ID: 0317700 -- Event Date: 06/25/2012
InspectionOpen DateSICEstablishment Name
490479.01506/28/2012Clark'S Garage
At approximately 5:00 p.m. on June 25, 2012, an employee was using an oxygen/pro pane cutting torch to remove the top lid from a 55-gallon steel drum. The drum p reviously contained methanol. The flammable vapors of methanol in the drum ignit ed causing the drum to explode. The employee was struck in the head by a part of the exploding drum lid. The employee was killed.
Keywords: drum, explosion, flying object, methyl alcohol, propane torch, steel, struck by, torch
Employee # Inspection Age Sex Degree Nature Occupation
1 490479.015 26 M Fatality Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.