Accident: 202658357 - Painter Falls And Fractures Hand And Cuts Forehead

Accident: 202658357 -- Report ID: 0950643 -- Event Date: 08/27/2013
InspectionOpen DateSICEstablishment Name
31667118909/11/20131721T & T Improvements Inc.
At approximately 11:30 a.m. on August 27, 2013, Employee #1, a painter, and coworkers, all employed by the painting contractor T & T Improvements Inc., were painting the exterior side walls of a multifamily residential building. Employee #1 was working from the sloped roof of the porch, which had a pitch of 4:12. He fell approximately 9 feet to the concrete surface below. Emergency services were called, and Employee #1 was transported to Providence holy Cross Medical Center. He was admitted and treated for a fractured hand and a cut to the forehead. Employee #1 remained hospitalized for six days. The employer notified Cal/OSHA of the incident at 3:45 p.m. on August 27, 2013. During Cal/OSHA's subsequent investigation, it was determined that Employee #1 had been working as a painter for T & T Improvements for approximately five months. At the time of Employee #1's fall, he was working adjacent to coworkers and the site supervisor. Interviews were conducted with Employee #1, Employee #1's supervisor (partial interview), and injured coworkers. The investigation concluded that Employee #1 had not been using or required to use approved fall protection, and the Primary Employer, Barrett Business Services Inc., did not ensure or verify that at the time of Employee #1's fall he was using or required to use approved fall protection. This violation of CCR Title 8 Section 1670(a) was determined to be the cause of the fall. Cal/OSHA issued a Serious Accident Related citation to the Secondary Employer, T & T Improvements, and a General citation to the Primary Employer, Barrett Business Services (the latter citation due to lack of evidence of employer knowledge) according to CCR Title 8 Section 1670(a).
Keywords: fracture, wall, forehead, construction, laceration, fall, fall protection, painter, hand, slope
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Multi-family dwelling Other Under $50,000 2 20
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 316671189 Hospitalized injury Fracture Painters, construction and maintenance FallDist:
FallHt:9
Cause: Exterior painting
FatCause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.