Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 202584843 - Jackhammer'S Broken Bit Crushes Employee'S Foot

Accident: 202584843 -- Report ID: 0950633 -- Event Date: 11/17/2008
InspectionOpen DateSICEstablishment Name
31060525812/19/20081623Foosco Inc
At approximately 11:09 a.m. on November 17, 2008, Employee #1 was working as a concrete laborer at a street walkway in Chino Hills, CA. He was a regular employee of his employer. His employer was installing an underground conduit for low-voltage communication lines. Employee #1 was breaking a concrete slab walkway with an APT Model Number 180 pneumatic jackhammer when a 2-foot-long bit broke. The bit shank struck the work boot on his left foot, piercing the boot and causing a serious crushing injury to his foot. He was taken to the Loma Linda University Medical Center in Loma Linda, California, for treatment. Surgery was performed, and he was hospitalized for two days.
Keywords: demolition, telecom work, conduit, jackhammer, equipment failure, crushed, undrgrd installation, concrete, foot
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Highway, road, street Other Under $50,000
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 310605258 Hospitalized injury Puncture Construction laborers FallDist:
FallHt:
Cause: Cutting concrete pavement
FatCause: Other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close