Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 202560728 - Employee Amputates Right Arm, Left Fingers Using Baler

Accident: 202560728 -- Report ID: 0950411 -- Event Date: 05/12/2009
InspectionOpen DateSICEstablishment Name
31339803405/12/20095131Tiedemann Globe, Inc.
On May 12, 2009, Employee #1 was operating a baler machine. The employee sustained partial amputation of the right arm and four fingers on the left hand while operating the machine. No additional information was provided in the narrative.
Keywords: amputated, finger, farm machinery, baler, arm
Employee # Inspection Age Sex Degree Nature Occupation
1 313398034 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close