Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Alert: Due to routine maintenance on the OSHA website, some pages may be temporarily unavailable.
To report an emergency, file a complaint with OSHA or ask a safety and health question, call 1-800-321-6742 (OSHA).

Accident Report Detail

Accident: 202552733 - Employee Dies From Heart Attack

Accident: 202552733 -- Report ID: 0950631 -- Event Date: 02/21/2011
InspectionOpen DateSICEstablishment Name
31316944303/07/20117371American Arium
On February 21, 2011, Employee #1, a controller, was discovered unconscious at her desk. She was taken to a nearby medical facility, where she died. It was determined that she died of natural causes, likely as a result of a heart attack.
Keywords: cardiovasc system, chest, unconsciousness, heart attack, cardiovasc disease
Employee # Inspection Age Sex Degree Nature Occupation
1 313169443 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close