Accident: 202531646 - Employee Is Caught Between Hoist And Tank, Later Dies

Accident: 202531646 -- Report ID: 0950635 -- Event Date: 03/13/2013
InspectionOpen DateSICEstablishment Name
31364764603/13/20133471Prime Wheel Corporation
At about 8:30 a.m. on March 13, 2013, Employee #1, with Prime Wheel Corporation, was wearing a long glove and was reaching into one of the plating tanks to feel for flow next to a filter intake that had been recently serviced. The process involved two lines of dip tanks. The baths included varying compounds of copper, chrome, acids, bases and other rinse baths. The two rows of dip tanks were serviced by overhead hoists with hangers, three on one side, four on the other. The process was computer controlled. Employee #1 was a member of the third shift. The second shift had completed a replacement of seals on a pump, a common practice job, and it was left for third shift to change and test the filter for the pump, which was also a common task. Employee #1 was feeling for flow when one of the automated hoists ran into him and pinned him against the tank. Employee 1# was trapped for several minutes as other coworkers tried to free him. Employee #1 was transported to the hospital but died around 9:30 a.m. The hoists were equipped with flashing light, horn and had interlocked shut-off safety bars on them. Most of these safety features were either disconnected, defeated, corroded or otherwise non-functional. On the hoist, represented to be the one involved in the accident, it was observed that the interlock switch was not engaged against the safety bar surface, rendering it inoperable, and there was no warning horn and no flashing light. The hoist appeared to have been manufactured by an Auto Technology Company in Strongsville, Ohio. It was determined that although Employee #1 had been hired originally via a temporary agency, at the time of the accident, Employee #1 had been hired as a full time employee of the employer. It was determined that the employer did provide personal protective equipment including safety glasses, gloves, steel toe boots and hardhats, but it could not be discerned from witness interviews whether the Employee #1 had been wearing this same equipment at the time of the accident. An Order Prohibiting Use (OPU)was hung on the plating line until repairs to the lights, horns and safety bars could be affected. The OPU was removed after all hoists had been restored with their safety features.
Keywords: horn, ppe, pinned, interlock, hoist, caught between, disconnecting means, tank
Employee # Inspection Age Sex Degree Nature Occupation
1 313647646 Fatality Other Not specified mechanics and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close