Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 202508628 - Employee Is Killed In Bulldozer Rollover

Accident: 202508628 -- Report ID: 0950622 -- Event Date: 08/29/2011
InspectionOpen DateSICEstablishment Name
31432849308/29/20111629Blattner Energy, Inc.,
On August 29, 2011, Employee #1 was working as a bulldozer operator on a highway construction project. Employee #1 was operating a D9T Caterpillar Bulldozer and was cutting a roadway winding around a 200 foot tall hillside. Employee #1 was not wearing a seatbelt. The bulldozer rolled over, and Employee #1 was ejected from the cab. The bulldozer rolled over Employee #1, crushing and killing him.
Keywords: highway, roll-over, crushed, seat belt, bulldozer
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Powerplant New project or new addition $20,000,000 and over 1 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 314328493 Fatality Other Occupation not reported FallDist:
FallHt:
Cause: Site grading and rock removal
FatCause: Crushed/run-over/trapped of operator by operating

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.