Accident: 202492922 - Employee Is Injured When Struck By Insulation

Accident: 202492922 -- Report ID: 0950621 -- Event Date: 02/01/2012
InspectionOpen DateSICEstablishment Name
12582795603/06/20121761Watson Roofing
On February 1, 2012, Employee #1 was working for his employer, a roofing contractor. Employee #1 was located on a roof and moved a load of insulation in a wheeled cart across the roof. There were two units of insulation in the load, and each unit weighed approximately 400 pounds. Employee #1 pulled on the cart and the cart tipped forward off the cart, striking Employee #1. One of the units pinned Employee #1 to the roof. Employee #1 suffered a fractured neck and was hospitalized for treatment of his injury.
Keywords: fracture, pinned, roofer, neck, struck by, thermal insulation
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Commercial building Maintenance or repair $50,000 to $250,000 2 22
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 125827956 Hospitalized injury Fracture Roofers FallDist:
FallHt:
Cause: Roofing
FatCause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.