Accident: 202476081 - Employee'S Arm Is Lacerated In Screw Conveyor

Accident: 202476081 -- Report ID: 0950636 -- Event Date: 07/21/2009
InspectionOpen DateSICEstablishment Name
31266176208/25/20093273Beacon Concrete Inc
At approximately 8:00 a.m. on July 21, 2009, Employee #1 was servicing a Bibko Ready Mix Recycling System, Model Number 2000, Serial Number 907/05, a cement recycler. He asked a coworker to turn the machine off, and the coworker reported that he did that. In order to make a gap adjustment on the screw conveyor, Employee #1 used a pneumatic chipper to remove dried cement from the adjustment bolt. The machine started its automatic cycle, and Employee #1's arm became caught in the screw conveyor. He suffered a deep laceration that required hospitalization for treatment. The equipment had not been turned off and was not locked or tagged out.
Keywords: maintenance, screw conveyor, lockout, chipper, laceration, arm
Employee # Inspection Age Sex Degree Nature Occupation
1 312661762 Hospitalized injury Cut/Laceration Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close