Accident: 202468252 - Employee Is Crushed And Killed By Cardboard Baler

Accident: 202468252 -- Report ID: 0950643 -- Event Date: 10/23/2009
InspectionOpen DateSICEstablishment Name
31243467310/23/20097699Micro Solutions Enterprises
On October 23, 2009, Employee #1 was operating a large, 30-foot-long industrial baler, which had a compaction area and a baling area. According to a percipient witness, Employee #1 entered the charging area, the unprotected danger zone, which is approximately 4 feet wide by 4 feet deep by 4 feet high. The baler had a light beam that triggered the ram when the charging area was full. The bailing area was completely full, and the baler ram came forward and crushed Employee #1 against the compacted cardboard. Employee #2, who was nearby, heard Employee #1's cries for help. Employee #2 went to the machine and pushed the stop button for the ram. Employee #1 was killed at the scene. No one witnessed the actual incident or knew why Employee #1 entered the charging area.
Keywords: lockout, crushed, baler, struck by, ram
Employee # Inspection Age Sex Degree Nature Occupation
1 312434673 Fatality Other Compressing and compacting machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close