Accident: 202455432 - Employee Is Crushed And Killed In Compacting Machine

Accident: 202455432 -- Report ID: 0950642 -- Event Date: 07/13/2009
InspectionOpen DateSICEstablishment Name
31049584107/13/20095311Macy'S Inc Dba Macy'S Stores Of California
At approximately 7:45 a.m. on July 13, 2009, Employee #1 was working as a recycler and was operating a Balewel by Bailmaster compacting and baling machine (Serial Number B02##-02-24930C). This machine was used to compact and bale corrugated waste material and was composed of a hopper, feed chute, charging chamber and baling section. Corrugated material was fed into the machine from a chute at the end of a conveyor located inside the establishment or dropped into the hopper by hand or a forklift. The hopper directs the material into the charging chamber where it is compacted by the ram and pushed into the bailing section of the machine. Manual and automatic modes of operation can be selected and an electronic eye system located just above the charging chamber initiates the compactor ram in the automatic mode when the beam is broken. At the time of the incident, the machine was set in the automatic mode and the electronic eye beam was blocked by a piece of plywood causing the compacting ram to continuously cycle. A pallet was placed on the baling portion of the machine next to the hopper where employees normally stand to push the corrugated material into the charging chamber. The height of the hopper from the pallet measured approximately 38-in. A protective metal box measuring approximately 6.5-in. square was covering the electronic eye was located approximately 24-in. from the top of the hopper. At the time of inspection a metal ladder stand measuring approximately 3-ft in height was located adjacent to the feed chute of the machine in an area where the wall of the chute narrowed from 24-in. to 12-in. in height. The work platform near the hopper and the narrowed area of the feed chute represent the most likely areas where E1 could have entered the machine. Employee #1's body was found in the baling section of the machine and showed signs of severe crushing injuries to the upper body. Employee #1 was killed.
Keywords: crushed, baler, conveyor
Employee # Inspection Age Sex Degree Nature Occupation
1 310495841 Fatality Other Compressing and compacting machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close