Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 202454526 - Employee 'S Finger Is Amputated After Crushed By Steel Roll

Accident: 202454526 -- Report ID: 0950642 -- Event Date: 03/05/2008
InspectionOpen DateSICEstablishment Name
31049094103/14/20082043General Mills Inc
At approximately 1:45 p.m. on March 5, 2008, Employee #1, a 30-year employee for General Mills, was working on the first floor of the milling department of the facility. Located on this floor were over 20 milling machines known as roll stands, as well as a computer control station for the operation. A roll stand is a piece of equipment that is used in the grain milling process and is comprised of four steel rolls that grind course wheat flour into a fine powder. The steel rolls are mounted in two horizontal pairs known as "breaks" one above the other and are powered by two 230/460 volt, 1,180 rpm and 1,800 rpm motors. Above the rolls is a product hopper where the product is fed into the machine from the second floor. At the bottom of each pair of rolls are brushes that prevent accumulation of the product on the rolls. Employee #1 noticed that the product was flowing through only one of the Buhler roll stands, Serial Number 10307027, known as "C-mill". After going to the computer station to identify the problem, he found that C-mill was in a suspended state meaning that the rolls were running but no product was flowing through the mill. He went to the roll stand and opened the access hatch to the upper set of rolls, where he found that the product had accumulated on top of the lower rolls. The access hatch of the machine was not interlocked and the rolls continued to run after the hatch was opened. Using an air hose with a 25.5-inch wand and wearing a pair of cotton work gloves with rubberized traction dots on them, Employee #1 began to blow the product out of the machine but he could not get all of it out of the corners of the rolls and off of the brushes. While the machine was still energized and the rolls running, he began cleaning the product off of the rolls with his left hand while using the air hose with his right. In order to clean the product out of the brushes, he held the outside brush from underneath and began to shake it out. His hand became caught in the machine at the right corner where the brushes meet the roll, crushing his fingers. He was admitted to the hospital and his finger was amputated.
Keywords: amputated, finger, grain, cleaning, milling machine, roller--mach/part, caught between, crushed, hopper
Employee # Inspection Age Sex Degree Nature Occupation
1 310490941 Hospitalized injury Amputation Crushing and grinding machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close