Accident Report Detail
Accident: 202366720 - Employee Is Struck And Killed By Top Pick At Marine Terminal
Accident: 202366720 -- Report ID: 1055320 -- Event Date: 04/19/2007 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
310951330 | 04/19/2007 | 7379 | Eagle Marine Services Ltd | ||||
On April 19, 2007, Employee #1 was working at a marine terminal. His occupation is not stated, but the report's SIC, 7379, is for a computer consulting firm (which might be mistaken). He was working in close proximity to a large top pick/PIT (powered industrial truck), assisting in offloading intermodal shipping containers from rail cars at the terminal. As the driver of the top pick/PIT was backing it up and turning it to his right, repositioning it to move another container, Employee #1 went under the left front tires and was killed immediately. Though the top pick/PIT was equipped with a back up alarm, the alarm was found to be inoperative when checked after the accident. No other equipment deficiencies were noted. | |||||||
Keywords:
back-up alarm, ind trk operator, inadequate maint, industrial truck, abrasion, struck by, containerized cargo, dock worker, backing up, contusion
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 310951330 | Fatality | Bruise/Contus/Abras | Occupation not reported |