Accident: 202340063 - Employee Crushed And Killed By Elevator
Accident: 202340063 -- Report ID: 0215000 -- Event Date: 12/06/2001 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
304944275 | 12/07/2001 | 7011 | Hotel Carter | ||||
Employee #1, a hotel maintenance superintendent, was on the top of a passenger elevator car while attempting to repair the car doors. The electro-mechanical door interlocks had been bypassed by the application of a jumper wire between the appropriate terminals in the control room. An unplanned start up caused the elevator car to move upward crushing and killing Employee #1 between the car and the hoistway door opening. | |||||||
Keywords:
repair, hoist, lockout, crushed, elevator, door
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 304944275 | Fatality | Other | Supervisors, cleaning and building service workers |