Accident: 202288536 - Employee Killed In Fall When Roofing Joist Collapses

Accident: 202288536 -- Report ID: 0950411 -- Event Date: 08/24/2007
InspectionOpen DateSICEstablishment Name
31138185908/24/20071751Sunrize Quality Framing, Llc
On August 24, 2007, Employee #1 and a coworker were installing roof sheathing. Employee #1 moved onto a roofing joist that gave way after he stepped on it. He fell 10 ft 1 in. onto a concrete floor and was killed. On the day before the accident, Employee #1 and coworkers had installed the joists, but not the joist hangers, which were not in supply at the site. This meant that one end of the roof joists was toe-nailed into the header, without the hangers to support it. When Employee #1 stepped on the joist, the two nails securing it to the header did not hold, causing that end of the joist to collapse.
Keywords: installing, joist, roof, collapse, unsecured, work rules, construction, fall
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Single family or duplex dwelling New project or new addition $250,000 to $500,000 1 10 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 311381859 Fatality Other Carpenters FallDist:
FallHt:10
Cause: Exterior carpentry
FatCause: Fall from roof

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.