Accident Report Detail
Accident: 202220752 - Employee Is Struck By Machine Carriage And Is Killed
Accident: 202220752 -- Report ID: 0111100 -- Event Date: 03/22/2010 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
314236381 | 03/23/2010 | 2435 | Columbia Forest Products, Inc. | ||||
On March 22, 2010, Employee #1, a maintenance crew leader, entered a Splice Line Automatic Number Four Stacker to clean dust off the photo cell lens. Employee #1 entered the stacker without applying lockout/tag out procedures. Employee #1 wiped off the dust and immediately the stacker's upper steel carriage retracted. The carriage's metal edge struck Employee #1 on the head and pinned him against the lower carriage. Employee #1 suffered a deep and severe laceration to the head and was killed. | |||||||
Keywords:
head, maintenance, dust, pinned, cleaning, lockout, laceration, struck by, housekeeping, machine--misc
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 314236381 | Fatality | Cut/Laceration | Machinery maintenance occupations |